Tool Tip: BMW A/C System Leak Testing Procedure Update

Tool Tip: BMW A/C System Leak Testing Procedure Update

The customer complains of poor or no air conditioning cooling. After further diagnosis, the system is found to be low or empty of a refrigerant charge, but when using an electronic leak detector, no leak can be found. Before replacing parts, perform a nitrogen leak test to confirm the location of the leak.

Models affected:

E82, E88 (1 Series)
E46 (3 Series)
E90, E91, E92, E93 (3 Series)
E60, E61 (5 Series)
E63, E64 (6 Series)
E83 (X3)
E70 (X5)
E71 (X6)
E85, E86 (Z4)

Situation
The customer complains of poor or no air conditioning cooling. After further diagnosis, the system is found to be low or empty of a refrigerant charge, but when using an electronic leak detector, no leak can be found.

Before replacing parts, perform a nitrogen leak test to confirm the location of the leak.

Cause
In some cases, an electronic leak detector is not sufficient for identifying small leaks in the system. Electronic leak detectors can give false alarms and can lead to an improper diagnosis of small leaks. A leak cannot be located exactly if accessibility is impaired (in the case of the expansion valve, evaporator or condenser).

Procedure

Always use proper eye and hand protection whenever servicing air conditioning systems. Refer to repair manual RA 64 50… for further information.

1. Always troubleshoot and correct any faults in the IHKA/IHKR (Independent Heating and Air Conditioning) system before proceeding further.

2. Use symptom diagnosis to determine if the system is low or empty of a refrigerant charge (refer to SI B64 04 07).

3. If the source of the leak is difficult to detect, the evaporator and condenser area needs to be checked further for leaks.

4. A special testing adapter set (64 5 120) has been developed, which allows pressure testing of the air conditioning evaporator and condenser while they are still installed in the vehicle. This prevents a lot of unnecessary disassembly of the vehicle for diagnosis purposes.

5. In order to use this adapter set, the following auxiliary materials will be needed:

• Nitrogen (in a pressurized cylinder) obtained locally. Ensure that employees are advised of how to handle pressurized cylinders correctly (danger of asphyxiation). For this purpose, follow the notes and instructions in the technical safety specifications, available from the gas supplier.

• Nitrogen tank set with pressure reducer.

• Refer to SI B04 24 08 for tool information.

6. If the evaporator or condenser is suspected of leaking, recover the remaining refrigerant from the system using a BMW-approved refrigerant recovery ­machine.

7. Refer to the repair manual instructions “RA 64 51 … Leak-testing condenser” for instructions on what adapters are needed, and the procedure for checking the condenser for leaks while installed in the vehicle.
figure 1
8. Once the proper adapters have been fitted, connect the nitrogen bottle (Figure 1, 1) with the pressure reducer (2) to the pressure gauge (3). Connect the special hose (64 5 121) to the fitting on the pressure gauge and the test adapter on the vehicle.

Note:

– The testing apparatus must be leakproof.
– Ambient temperature and the temperature of the vehicle must not change significantly during the test procedure.
– The vehicle must not be moved during the test period.

9. Ensure that the regulator (Figure 2, 1) is backed off and the flow shutoff valve (2) is closed.
figure 2
10. Open the nitrogen bottle valve slowly.

11. Open the valve (2) to the full open position. Note: The valve is shown in the closed position.

12. Apply test pressure of 10 bar (150 psi) slowly by turning the pressure regulator (1) clockwise.

13. A pressure of 20 bar (280 psi) must not be exceeded, as this will damage the evaporator or other system components.

14. Once the test pressure of 10 bar (150 psi) is reached, close the valve (2). Back off the regulator and close the ­nitrogen bottle valve.

15. Check the leak tightness of the testing apparatus and of the connections at the adapters.

16. Monitor the pressure over a period of two hours. Pressure should remain constant at 10 bar (150 psi), Figure 3.
Figure 3
17. Any drop in pressure indicates that there is a leak in the evaporator or condenser, depending on which component is being tested.

18. Release the residual pressure from the line, using the pressure relief valve.

19. Replace the evaporator or condenser as needed.

After leak testing and repair:

– Retest the system using the same procedure to ensure that there are no leaks.

– Release all pressure from the test hose slowly.

– Replace all sealing rings before reassembly.

– Evacuate and fill the system.

Courtesy of ALLDATA

You May Also Like

BCA Bearings Unveils 2024 Endless Summer Promotion

The Endless Summer promotion runs from May 1 through June 30, 2024.

NTN, the parent company of BCA Bearings, is proud to announce the launch of BCA’s 2024 Endless Summer promotion. During the promotion, BCA’s warehouse distributor customers can earn BCA-branded, premium merchandise with orders of BCA wheel hub assemblies, bearings and seals.

“We are thrilled to announce the BCA Endless Summer promotion” said Patrick Cronin, Marketing Manager, Automotive Aftermarket. “The Endless Summer theme evokes a relaxed and carefree feeling that we all strive to achieve; the same carefree feeling we want associated with using our premium parts. We are looking forward to summer and another great promotion.”

VW/Audi PCV Service

The PCV valve regulates the flow of gases from the crankcase.

Volvo Engine Service

There are many combinations for the Volvo modular engine.

Servicing Mercedes-Benz AMG Brakes

Take a look at some of the things you need to know in order to service the brakes on a Mercedes-Benz AMG vehicle.

AUDI Outside Air Temperature Readings

Incorrect readings can be avoided.

Other Posts

Don’t Miss The April Digital Edition of ShopOwner

The April issue includes technical and management content and is free to download.

Nissan Vehicle Key Not Detected and Engine Will Not Start

Refer to the service information for complete key system diagnosis and repair information.

ZF Expands SACHS CDC Shock Line for U.S., Canada

The release expands ZF’s line by more than 70% reflecting growing demand for advanced damping technology in the aftermarket.

Philips Announces Xperion 6000 LED Under Hood Work Light

It features a motion detection switch that allows mechanics to turn the light on and off with a wave of their hand.